Power quality analyzer - All industrial manufacturers

22 Jul.,2024

 

Power quality analyzer - All industrial manufacturers

... gaps Our precision power quality analysers will perform 'gap-less' measurement and capture all details of every power cycle during measurement and logging; this capability ...

You will get efficient and thoughtful service from SUIN.

See the other products KEYSIGHT TECHNOLOGIES

See the other products KEYSIGHT TECHNOLOGIES

Make all of your critical power measurements faster and easier using one instrument Enhance AC power measurements with touch-driven dynamic views The Keysight IntegraVision power ...

Online display Analyzer / Controller/ Transmitter for 4 Parameters overview: This Online display Analyzer / Controller/ Transmitter for 4 Parameters is a new intelligent controller with ...

... controller/ Single Parameter Analyzer is a new intelligent controller with high intelligence and flexibility, Identifying all our sensors, and is widely used in aquaculture, municipal sewage treatment ...

for the food industry

monitoring for electrical networks for the food industry

See the other products Contrel elettronica

See the other products Contrel elettronica

... outputs using an alarm. The analyzer can accept up to 4 digital inputs. Range - EMA Product name - EMA-D6 Product type - Network analyzer Device application - Energy and power monitoring Multi-tariff Sub-billing Power ...

See the other products Contrel elettronica

See the other products Contrel elettronica

... Network analyzer Technical characteristics Device application Energy and power monitoring Multi-tariff Sub-billing Gateway Power quality analysis Up to the 63rd ...

See the other products Contrel elettronica

See the other products Contrel elettronica

Power analyzer for panel with power quality measurement parameters Range - EMA Product name - EMA-11N Product type - Network analyzer Device ...

... 100x faster SampleTime as Rev.3 &#; Up to 80 dB higher sensitivity as Rev.3 Powerful handheld spectrum analyzer . The 9.4 GHz spectrum analyzer for the "pro" at an incredible price, leaving (almost) ...

MiniLab 153 - Comprehensive Oil Analyzer For Industrial Machinery MiniLab is a comprehensive oil analysis lab for industrial plants and power plants Oil analysis provides early indications of equipment ...

This unique device helps identify stress points on transparent and translucent plastics and polymers. Utilizing the principle of polarization, two film plates are turned to provide the optimal viewing index. Stress points are easily viewed ...

MIDO 96 - Electrical network analyzer - 96x96mm built-in The MIDO6D series three-phase panel analyzers for DIN rail mounting are instruments for measuring electrical quantities. The devices allow ...

MIDO 6D - Electrical network analyzer - 6 Din modules The MIDO6D series three-phase panel analyzers for DIN rail mounting are instruments for measuring electrical quantities. The devices allow the ...

See the other products Algodue Elettronica

See the other products Algodue Elettronica

... Three-phase multifunction meter DIN rail mounted with 3 MFC150 Algodue Rogowski coils UPM209RGW is an innovative network analyzer for the measurement and data recording of electrical parameters , particularly compact ...

See the other products Algodue Elettronica

See the other products Algodue Elettronica

... Three-phase multifunction meter panel mounted with 3 MFC150 Algodue Rogowski coils UPM309RGW is an innovative network analyzer for the measurement and data recording of electrical parameters , particularly compact ...

See the other products Algodue Elettronica

See the other products Algodue Elettronica

UPM309 three-phase multifunction electrical meter panel mounted UPM309 is an innovative network analyzer for the measurement and data recording of electrical parameters , particularly compact (less than 4 cm thick) ...

See the other products Newtons4th Ltd.

See the other products Newtons4th Ltd.

The PPA Power Analyzer offers higher performance than its sibling &#; the PPA500 unit, the PPA series ensures that N4L power analyzers provide the optimum solution ...

See the other products Newtons4th Ltd.

See the other products Newtons4th Ltd.

The PPA500 joins Newtons4th&#;s Precision Power Analyzer range addressing a need for high performance power analysis at low cost. Primarily aimed toward applications that require precision ...

See the other products Newtons4th Ltd.

See the other products Newtons4th Ltd.

... PPA power analyzer benefits from a full color &#;Dual&#; TFT display, this concept employs two TFT displays within one instrument, allowing for a large widescreen display area in a 2U form factor. Why ...

Compact, stand-alone, tube base MCA including high voltage power supply (0 ÷ +V / 500 µA) and charge sensitive preamplifier On-board battery and data storage capability for active on-field measurements Embedded ...

See the other products TES Electrical Electronic Corp.

See the other products TES Electrical Electronic Corp.

... logging for PROVA &#; 210/218: 0 ~ 99 min. &#; Large LCD with backlight &#; Quality control in the production line, warehouse, or site of installation. &#; Identify the solar power system requirement. &#; ...

See the other products TES Electrical Electronic Corp.

See the other products TES Electrical Electronic Corp.

... capacitance to improve PF &#; Direct display of Power Factor (PF) &#; Datalogging of sets of records (WM-03) &#; Power device research and development &#; Production Q.C. (eg. Home appliance) &#; Field ...

See the other products TES Electrical Electronic Corp.

See the other products TES Electrical Electronic Corp.

&#; Power Analysis for 3P4W, 3P3W, 1P2W, 1 P3W &#; True RMS value (V123 and ) &#; Active Power (W, KW, MW, GW) &#; Apparent and Reactive Power (KVA, KVAR) &#; Power Factor ...

See the other products Rayfull Electric Technology(Zhejiang)Co., Ltd.

See the other products Rayfull Electric Technology(Zhejiang)Co., Ltd.

EI920 series are three phase multifunctional power analyzer to measure and analyze most important electrical parameters, including voltage, current, four-quadrant power parameters, power ...

See the other products Rayfull Electric Technology(Zhejiang)Co., Ltd.

See the other products Rayfull Electric Technology(Zhejiang)Co., Ltd.

EI910 series are three phase multifunctional power analyzer to measure and analyze most important electrical parameters, including voltage, current, four-quadrant power parameters, power ...

See the other products Rayfull Electric Technology(Zhejiang)Co., Ltd.

See the other products Rayfull Electric Technology(Zhejiang)Co., Ltd.

EI900 series are three phase multifunctional power analyzer to measure and analyze most important electrical parameters, including voltage, current, four-quadrant power parameters, power ...

... Introduction The DW- is a three-phase power analyzer manufactured by Lutron Corporation. It can measure three-phase voltage, current, power , power factor, frequency, ...

See the other products METREL

See the other products METREL

... selection &#; Sampling frequency on transients recording 30 kSamples/sec &#; Compliance with power quality standard IEC -4-30 Class S &#; Complete power quality analysis ...

See the other products METREL

See the other products METREL

The MI Power Master is a hand-held three phase power quality ana­lyser with a large easy-to-read graphical colour display enabling the user to detect harmonics, phasors and waveforms ...

See the other products METREL

See the other products METREL

... measurement &#; Power factor, cos fi and tg fi KEY FEATURES &#; Sampling frequency on transients recording > 1 MSamples/sec, on 8 channels simultaneously &#; Compliance with power quality ...

See the other products GOSSEN METRAWATT GmbH

See the other products GOSSEN METRAWATT GmbH

The MAVOWATT 230 enables users to review data and change settings remotely from virtually any smartphone, tablet mobile device, as well as with traditional PC and MAC laptops and desktops. Just hook up the instrument, close the cabinets ...

See the other products GOSSEN METRAWATT GmbH

See the other products GOSSEN METRAWATT GmbH

MAVOWATT 270 three-phase energy and power disturbance analyzers The MAVOWATT 230, 240, 270 product range is offering a new generation of world-class power quality , power ...

See the other products GOSSEN METRAWATT GmbH

See the other products GOSSEN METRAWATT GmbH

If you want to learn more, please visit our website Handheld Power Quality Analyzer Manufacturers.

... offering a new generation of world-class power quality , power and energy measuring instruments for measurements in V CAT III and 600 V CAT IV applications. The new MAVOWATT ...

... mass filter power supply and a Merlin CS (Command System). The Merlin mass spectrometer controller software completes the system. Our MAX Systems are based on our industry leading mass spectrometer technology centered ...

... clamp is able to calculate effective, apparent and reactive power with the help of the phase angle. In addition, the current clamp can measure other network parameters such as the energy, power factor ...

See the other products SENECA | Automation Interfaces

See the other products SENECA | Automation Interfaces

... analog retransmission (ma or V). 3-way galvanic isolation among Power supply // input // RS485 circuits assures the integrity of your data. Description: - Advanced single-phase network analyzer Voltage ...

See the other products SENECA | Automation Interfaces

See the other products SENECA | Automation Interfaces

... three-phase, or any phase chosen (by specific display or MODBUSregistry) Description: - AC three phase network analyzer with energy meter Power Supply: - 10-40 Vdc; 19-28 Vac Voltage Input: - ...

See the other products SENECA | Automation Interfaces

See the other products SENECA | Automation Interfaces

... harmonics up to the 55th order, with THD (total harmonic distortion) calculation, enabling a complete understanding of power quality

FDS-PDC+ dielectric insulation analyzer DIRANA uses dielectric frequency response (DFR) analysis in order to determine the condition of high-voltage insulation systems such as those in power transformers, ...

FRANEO 800 was developed for testing the mechanical and electrical integrity of power transformers after transportation or exposure to high fault currents. It uses the sweep frequency response analysis (SFRA) principle ...

Hybrid signal analyzer for power utility automation systems DANEO 400 is a hybrid measurement system that records and analyzes all conventional signals (voltages, currents, hard wired binary status ...

... functions for further analysis of electricity network. It measures voltage, current, active power , frequency, and through calculation also reactive power , apparent power and cos fi. The ...

See the other products CIRCUTOR

See the other products CIRCUTOR

Three-phase power analyzer (balanced and unbalanced) for mounting on DIN rail, very compact, with measurements in 4 quadrants. Other features: Current measurement .../5 or .../1 A or .../250 mA With ...

See the other products CIRCUTOR

See the other products CIRCUTOR

CVM-A is a panel mounted power quality analyzer with EMS (Energy Management Software) integrated. Its internal Web Server (html5) allows any user to have full installation control ...

See the other products CIRCUTOR

See the other products CIRCUTOR

CVM-NET4-MC is a Power Analyzer used to measure balanced and unbalanced threephase networks; specifically designed to take measurements from 4 different points of the installation. It has a single three-phase ...

... gas, oil or biomass, including applications in Glass, Power Generation, Hydrocarbon Processing, Natural Gas Compressor Stations , Minerals and Industrial Boilers. MULTIGAS ANALYSIS MADE SIMPLE Power ...

ABB's Navigator 600 Silica analyzer substantially cuts the costs and maintenance associated with silica monitoring in power generation and other large-scale steam and water dependent applications. Many ...

Gasboard- online biogas analyzer is designed to measure CH4, CO2, H2S and O2 concentration simultaneously in different biogas applications, like landfill, water treatment, CDM projects, anaerobic digestion and other ...

Gasboard-L portable biogas analyzer is designed to measure CH4, CO2, H2S and O2 concentration simultaneously in different biogas applications, like landfill, water treatment, CDM projects, anaerobic digestion and ...

{{#if product.newProduct}}{{/if}} {{#if product.hasVideo}}{{/if}}

{{#each product.specData:i}} {{name}} : {{value}} {{#i!=(product.specData.length-1)}} {{/end}} {{/each}}

{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}

{{#if product.newProduct}}{{/if}} {{#if product.hasVideo}}{{/if}}

{{#each product.specData:i}} {{name}} : {{value}} {{#i!=(product.specData.length-1)}} {{/end}} {{/each}}

{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}

& reach your clients in one place, all year round

Modes of use

for the mining industry

for the chemical industry

for the food industry

& reach your clients in one place, all year round

Your answer has been taken into account. Thank-you for your help.

Your suggestions for improvement:

Evaluate the quality of the search results:

TELL US WHAT YOU THINK

Subscribe to our newsletter

Thank you for subscribing

There was a problem with your request

Invalid address

Receive updates on this section every two weeks.

Power Quality Measurement and Analysis Basics

Published by Randy Barnett, Certified Energy Auditor and Trainer for NTT, Centennial, Colo. : , March 1st, .

How to interpret the results of a power quality site survey

Analyzing electrical parameters associated with distributing electricity is viewed by many as complex engineering work. Yet, for engineers, electricians, and technicians troubleshooting equipment problems these days &#; and for contractors maintaining electrical systems they may have once installed &#; measuring power quality is becoming as much of a necessity as using the clamp ammeter to find out why the overloaded circuits keep tripping.

When any electrical system fails to meet its purpose, it is time to investigate the problem, find the cause, and initiate corrective action. The purpose of the electrical distribution system is to support proper operation of the loads. When a load does not operate properly, the quality of the electric power in the system should be suspected as one possible cause. Whether it&#;s used for troubleshooting purposes or to obtain baseline data, measuring/analyzing electrical system parameters is called power quality analysis.

The setup and use of power quality equipment &#; and obtaining and interpreting usable data &#; can be intimidating for those not familiar with the process. The key to success is knowing where and how to measure as well as how to interpret the results.

Organization and planning is key to success. Dedicating an equipment cart to hold analyzers, test equipment, drawings, manuals, notebook, digital camera, and safety equipment can help.

Measurement Tools

Several measurement tools are available for power quality measurement. Power quality analyzers are the most commonly used tools to observe real-time readings and also collect data for downloading to computers for analysis. While some are permanently installed in the distribution system, handheld analyzers are necessary for many applications, especially troubleshooting.

Handheld power quality analyzers are fairly lightweight (generally 4 lb to 5 lb) and will measure a variety of parameters. The most typical include voltage, amperage, frequency, dips (sags) and swells in voltage values, power factor, harmonic currents, and the resulting distortion and crest factor, power and energy, voltage and current unbalance, inrush current values, and light flicker. If an analyzer measures and records such basic parameters, you can address most power quality issues successfully.

Portable data loggers typically monitor many of the same parameters as the power quality analyzer; however, they are meant for long-term recording (days to several weeks). In addition, the data logger does not typically provide the real-time values on-screen that an analyzer can provide. Additional test equipment, such as scopemeters and recording digital multimeters, also find specific use applications.

The Process

Conducting a power quality survey begins with planning. Simply determine the purpose of the survey, and write it down in a notebook or binder that will be used throughout the process to organize and maintain data. Start with a good one-line diagram of the facility electrical distribution system. If one does not exist, then this is an excellent time to get one up to date.

If conducting a general power quality survey to obtain baseline data for future comparisons &#; or to help identify any immediate hidden electrical distribution problems that may exist &#; start monitoring as close as practical at the point of service. Beware, however, measuring near the service typically means large amounts of fault current available. Therefore, be careful when connecting the analyzer at a point in the distribution system downstream of the main breaker that limits incident energy levels to acceptable values. Because power quality problems can either come from the electric utility &#; or be generated within the facility &#; be sure to contact the utility in order to identify any possible issues on this side of the meter.

Inside the facility, continue to &#;drill down&#; into the distribution system following the one-line diagram. Obtain data at the source of each separately derived system. For example, take recordings at the first panelboard or switchboard after a 480V to 208Y/120V transformer. Be sure to mark up drawings, and take plenty of notes for future reference.

Digital cameras work well for quickly capturing nameplate data and later identifying exact connection locations. Note plant conditions and any equipment that was running. Print out digital pictures, and maintain all data for the survey in the notebook binder. These notes will become valuable when analyzing data and conducting further studies.

Follow manufacturer&#;s instructions for connecting and setting up the analyzer. Because of the amount of test equipment and supporting documentation that is needed, it is often best to have an equipment cart dedicated for power quality work. In addition to technical expertise, the underlying key to a successful survey is planning and organization. Three common mistakes when connecting power quality analyzers are:

  1. Failure to observe current polarity. Make sure the arrow on current clamps points toward the load. If the arrow points in the wrong direction, a negative current value is obtained on the analyzer for that phase.
  2. Not matching current/voltage probes. If analyzer input phase &#;A&#; is clipped onto phase &#;B,&#; it is obvious readings will be erroneous. Color code individual leads such that voltage and current leads for each phase are the same color, and connect carefully to prevent such errors.
  3. Relying on battery power to complete a lengthy monitoring session. While fully charged analyzer batteries are meant to last hours, nothing is more frustrating than to find key power quality events were not recorded because the analyzer shut down. Be sure to keep the analyzer plugged into an AC source for recording parameters when you will be away from the equipment.
Analyzing the Data

Whether observing values real-time on the analyzer color screen or analyzing downloaded data on the laptop back in the shop, an understanding of power quality parameters and their characteristics must be understood. IEEE Power Quality Standards and NFPA 70B are excellent resources to help understand power quality terminology, issues, and corrective actions. To help with data analysis, each manufacturer provides software for its specific test equipment. Here is what to look for when analyzing data:

If experiencing overheating of neutrals, overheating of transformers or motors, nuisance tripping of circuit breakers, blown fuses, unusual audible noise in larger distribution equipment, or if distorted voltage sine waves are found, then suspect harmonics. The magnitude of the various harmonic frequencies and the amount of total harmonic distortion created by the harmonics are the critical factors to determine the severity and correction techniques for any harmonic problem. Measure harmonics at their source, (e.g., VFD, UPS), and expect them to lessen further upstream from the equipment. Sine wave distortion is a good indicator that you should analyze harmonics values (Figures 1, 2, and 3).

Fig. 1. While performing a power quality survey in a commercial office, distortion of the current sine wave on phase &#;C&#; at a panelboard indicated nonlinear loads and potential harmonic problems.

Transients are extremely short-duration voltage surges, sometimes incorrectly called &#;spikes.&#; The voltage levels achieved during a transient can cause equipment problems ranging from malfunction to destruction. If you&#;re experiencing unusual insulation failures, record data for extended periods at the equipment. The most severe transients are often caused by nearby lightning strikes. However, they can also be the result of switching of loads.

Voltage sags and swells are the most common type of power quality culprits. While definitions provide specific numbers for magnitude and duration of changes up or down in voltage values, the bottom line is changes of 10% or more in either direction from normal voltage can cause problems. These conditions only need to last from ½ cycle to 1 min. Too high a voltage (swell) can occur when large loads are dropped off the line. Sags, the decrease in voltage, are typically more bothersome and can cause contactors and relays to chatter or drop out completely. Equipment such as PLCs and variable-speed drives can malfunction, and computers may lock up. Observe voltage recordings for sags and swells, and try to relate these variations to changes in plant conditions or operations, (e.g., a chiller or other large load cycling off or on).

Fig. 2. Switching the analyzer to the harmonic function found indications of primarily 3rd and 5th harmonics (180 Hz) on phase &#;C.&#; These harmonics can distort the voltage sine wave causing mis-operation of equipment and increasing heat on the neutral conductor &#; and in motor and transformer windings.

Voltage unbalance between phases on a 3-phase motor can cause current values to reach six to 10 times the value of the voltage unbalance. Because current causes heat &#; and overheating is one of the leading causes of motor failure &#; distribution systems should be monitored for unbalance. Unbalance is often the result of single-phase loads cycling off and on, so monitor for unbalance at panelboards and switchboards throughout a typical plant cycle.

Fig. 3. The concern is that the harmonic currents may severely distort the voltage sine wave causing distribution system problems. A normal crest factor (CF) should read 1.41 (Vpeak ÷ Vrms). Here, phase &#;C&#; voltage crest factor is 1.47, slightly higher than normal. The crest factor for amperage on phase &#;C&#; is 2.09.

The key to success in power quality measurement and analysis can be attributed to success in three key areas. Set goals and plan the survey by reviewing one-line diagrams to determine points to monitor. Learn the functions and features of the test equipment and how to use it to capture the needed values. Finally, know what to look for while observing data whether in the field or after it is downloaded to the computer. Learning how to successfully measure electrical parameters associated with proper operation of equipment is obviously a key step in solving power quality issues.

Source: https://www.ecmweb.com/power-quality-reliability/article//power-quality-measurement-and-analysis-basics

Are you interested in learning more about Handheld Power Quality Analyzer Dealers? Contact us today to secure an expert consultation!