Reliability and consistency of electricity supply is one of the most important conditions for the activities of industrial and service companies. Problems originating from poor Power Quality include interruptions, dips or harmonic pollution. Therefore the loads connected to a network with such problems will fail, have a short lifetime and the efficiency of the system will decrease.
According to Leonardo Energy organization the financial losses due to poor Power Quality amount to a total of 150 billion annually in the EU-25. And its impact in the rest of the world is in the same order of magnitude.
The ideal state of a load would have a constant magnitude and frequency voltage waveform. However this is not possible in real installations (outages, non-zero impedance, etc. ). The consequences of poor Power Quality include:
The evaluation of the quality of the power supply considers mainly two parameters:
There are many factors affecting the quality of electricity. Some of the most important ones are:
Power Quality monitoring is already a service provided by the grid utilities to their core customers (big industrial and commercial energy users). Anyway many studies have demonstrated that most of the problems happen within the customers facility. This fact means that monitoring the Power Quality after the utility meter provides a range of benefits both for the utility and end-user. This is even more true in a scenario where many end-users are also energy producers.
Monitoring the Power Quality will make possible to detect the sources/causes of problems within the end-users network. The solution would be either removing the source or making immune the installation from the the poor power quality. Both solutions usually cost far less than the potential damages that may derive.
Anyway still a large number of end-users do not invest in this field and ignore the efficiency that may derive from fixing the problems with poor Power Quality.
In addition to the lacking of informative awareness among stakeholders, one of the main reasons is also that the a large part of the cost of poor PQ is often hidden. Therefore a monitoring system is one of the fist steps toward the optimization of Power Quality.
Our Power Quality Energy Analyzer & Data Manager Electrex of the Kilo PQ product family, in addition to measuring and managing power consumption, are designed to monitor the Power quality and control whether the installation and the equipment handle properly the workloads.
The Kilo PQ devices are used for:
Power Quality (Class S EN -4-30): Events Log
The Kilo D6 PQ detects and logs various events with a resolution of one cycle (with date / time * of each event, type of event, phase involved, duration, min / max value reached during the event and UNIPEDE classification) useful for monitoring the quality of energy (functions related also to the EN and EN -4-30 standards for the S class). The parameters for defining abnormal events are programmable.
The parameters for defining abnormal events are programmable.
Event types:
(*) Date/hour expressed in hours, minutes, seconds and milliseconds referring to the instruments (local time). In the table are displayed also some functioning logs as the ones related with the start and configuration settings.
EVENTS GRAPHIC DETAIL
The Kilo D6 PQ includes the functionality named events graphic detail that allows to record and display the trends of the beginning and end of the event with a time frame (for both beginning and end) of a second (programmable).
Are you interested in learning more about Industrial Power Quality Analyzer Wholesaler? Contact us today to secure an expert consultation!
EVENTS TIMELINE AND THE UNIPEDE TABLE
The Kilo D6 PQ can display a timeline of the succession of events
and maintains a diagram of distribution of events based on the % of the parameter considered in relation to its reference value and duration, according to the dictates of UNIPEDE (International Union of Producers and Distributors of Energy).
Example: in the last column of the table here below , the S1 denotes a Voltage Swell with a duration between 10 and 500 mS (refer to the UNIPEDE table above), while the X2 denotes a Voltage Dip lower than 5% of the nominal voltage value with a duration between the 10 and 200 mS.
MEASUREMENT CAMPAIGN
With the Kilo D6 PQ it is possible to configure the measurement campaign in order to log, in the built-in memory, the various parameters with a programmable sampling.
Example of a daily measurement campaign of the 3 phase voltages:
Regarding the quality of the voltage the Kilo PQ refers to the European standard EN which distinguishes the different disturbances in continuous phenomena and voltage events.
The continuous phenomena include:
The voltage events include:
Origin of disturbances
Noises are always present in electrical networks and are mainly produced by:
Voltage quality indicators. What to measure.
The monitoring voltage quality examines the following parameters:
When running a Power Quality monitoring program, it is important to consider that the network changes continuously. Traditional measuring devices are not suitable for monitoring non linear loads as the equipment used must measure in True RMS and must specify the range of single Harmonic measured.