Cutout (left) attached to a feeder line (connection at the right not shown). The lower wire goes to the transformer A set of pole top cutouts (with C-shaped bodies) protecting a transformer on a 12.47 kV distribution line. One fuse is blown and the tube is hanging down. Lightning arresters are mounted on the crossarm opposite the fuse cutouts. Fuse cutouts with V-shaped bodies.In electrical distribution, a fuse cutout or cut-out fuse (often referred to as a cutout) is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to melt and the switch mechanism to visibly open, disconnecting the transformer from the line. The device can also be opened manually by utility linemen standing on the ground and using a long insulating stick called a "hot stick".
Components
[
edit
]
A cutout and fuse assembly consist of three major components:
The fuse holder may be replaced by a solid blade, which would allow the fuse holder assembly to be used as a switch only.
Construction
[
Contact us to discuss your requirements of what is the purpose of a washer. Our experienced sales team can help you identify the options that best suit your needs.
edit
]
The fuse elements used in most distribution cutouts are tin or silver alloy wires that melt when subjected to high enough current. Ampere ratings of fuse elements vary from 1 ampere to 200 amperes but a solid door will allow the full 300 ampere capacity of the cutout to be utilized.
Cutouts are typically mounted about 20 degrees off vertical so that the center of gravity of the fuse holder is displaced and the fuse holder will rotate and fall open under its own weight when the fuse blows. Mechanical tension on the fuse link normally holds an ejector spring in a stable position. When the fuse blows, the released spring pulls the stub of the fuse link out of the fuse holder tube to reduce surge duration and damage to the transformer and fuse holder. This quenches any arc in the fuse holder.
Linemen from Huntsville Utilities replace a blown cutout fuse with a non-conductive extending pole tool on July 10th, in Huntsville, Alabama.Each fuse holder typically has an attached pull ring that can be engaged by a hook at the end of a fiberglass hot stick operated by a lineworker standing on the ground or from a bucket truck, to manually open the switch. While often used for switching, the standard cutout shown is not designed to be manually opened under load. For applications where the switch is likely to be used to interrupt power manually, a "load break" version is available that has an attachment to quench the arc.
Standards
[
edit
]
Up until the mid-s each manufacturer used their own dimensional standards for cutout design; by the late s most cutouts were of an "interchangeable design". This design allows for the interchangeable use of cutout bodies and fuse holders manufactured by different vendors.