The leakage current test

13 May.,2024

 

The leakage current test

Do I feel safe?

Read more

Am I doing everything right?

You will know for sure in a few minutes.

Safety tests are mandatory and are part of every final inspection of your electrical product.
Learn the most important facts about the leakage current test.
We explain the WHY?, WHERE? and HOW?
And if you would like to learn more, you can download even more detailed information at the end of this page free of charge!

 

The INSULATION?

As is the case with the insulation resistance and high voltage test, the leakage current test is all about the quality and safety of the insulation.

The leakage current test takes place during the actual use of the electrical product. For this purpose, the electrical device is connected to the operating voltage and tested to see whether too high a leakage current flows through the insulation to the housing. It is therefore a combination of a safety and functional test.

 

WHY?

Safe insulation is the central protective measure to ensure electrical safety. It ensures that the user does not touch live conductors and that no short circuit can occur between the conductors or to the housing of the equipment. Because if it did occur, a life-threatening current could flow through the user if he or she touched the housing. Obviously, the protective earth conductor should ensure that this does not happen. But in the worst case it could also be defective. And it would also only be an evasion of the effect, not of the cause.

 

 

In order to guarantee all this, the insulation must work perfectly! And this must be proven and documented by you with a leakage current test before the electrical product is delivered.

This test is not mandatory for all electrical products. However, it may well be required for the certification of the electrical product in the type test. If it is required during manufacture, it is a routine test. This means that every piece, i.e. every single electrical product you put on the market, necessarily requires a leakage current test .

 

HOW?

Since the insulation has “something to do with the voltage”, the test is carried out with increased nominal voltage. The increase is typically + 6%, + 10% or + 15%. The reason: since the mains voltage could be increased by up to + 10% at the end customer’s premises, this should be simulated accordingly during the test. The electrical product is thus in an operating state with overvoltage.
This type of procedure has the advantage that during the test, as many components of the electrical product as possible are temporarily or permanently live.
The test is often referred to as the “warm leakage current test“. Logically, there is also the “cold leakage current test“. Consequently, the electrical product is not operated in this test. The test intensity is lower here.

The aim is to measure the current through the insulation in a wide range of fault conditions. This is because it is the evaluation criterion for the insulation. It must never be greater than a specified maximum current during the entire test period.
The upper limit of the leakage current can be defined differently from product to product and in different regions/continents. Therefore, you must take the test parameters from the standard applicable to the product and region.

The current measurement is not only a simple current measurement with a multimeter!
No, the user is simulated by various RC networks (resistor-capacitor networks). These are defined in the standards for different, possible error cases.

The test is carried out under various fault conditions automatically simulated by the tester.
The leakage current in the protective earth conductor of the electrical device is measured.

 

 

 

If there are housing parts on the electrical product that are not connected to the protective earth conductor, the test is performed using a test probe.

 

For 25 years, complex tests have therefore always been carried out automatically at any test points via the SCHLEICH-typical matrix, which is fully programmable:

 

Test paramters

typical norm values

SCHLEICH | from standard to customized

test voltage 1.05 – 1.1 x Unominal 1.0 – 1.15 x nominal voltage max. permissible test current 1 – 30 mA 1 µA – 500 mA minimum test duration 1 s from 0.1 s to 24 h measurement circuits EN60990 3 1. measurement circuits: unweighted touch current
2. measurement circuits: touch current evaluated for perception and reaction
3. measurement circuits: touch current evaluated for release measurement circuits EN60601 1 1. measurement circuits: EN60601 measurement circuits UL 1 1. measurement circuits: UL1026 + UL1283 measurement frequency 500 Hz, 1 MHz up to 500 Hz / 1MHz

With this range of requirements, it is of course ideal to use a test device that covers as many of the world’s standards as possible.
That is SCHLEICH’s strength.

 

LEAKAGE CURRENT up to 1 MHz ?

More and more modern electrical products have integrated electronic components. Very often switching power supplies are used for internal power supply. These can produce pulse-like leakage currents with very high frequency parts of up to 1 MHz. In order to be able to test these, the leakage current measurement technology must also be dimensioned to 1 MHz.

The effort involved is not inconsiderable.
SCHLEICH offers the 1 MHz leakage current test including factory calibration or DAkkS calibration! The harmonic response of the measuring circuit is also documented.

 

All set? Want more details?

Our mission – know-how, know-how, know-how… Those who understand the test methods with technical and normative certainty will get the most out of their test device.
– Dipl. Ing. Martin Lahrmann

Yes – tell me more. I want maximum security for our customers, our company and myself.

Send me more detailed information from the SCHLEICH test method handbook.

Δ

GLP2-BASIC

Protective conductor, insulation, high voltage, leakage current and function tester

  • insulation Resistance testers – IR
  • high voltage testers AC/DC
  • “All in one” testers
  • safety & function testers
  • app. 40 device variants – combined from up to 21 test methods
  • PLe, SIL3, Kat4 safety circuit (depending on device variant and degree of risk)
  • network
  • protocol & label printing
  • scanner …
  • Technology Package for even more ergonomics
  • table-top unit or 19″ rack mounting

read more

GLP2-MODULAR

Combination tester with up to 25 test methods

  • “All in one”
  • safety testers
  • safety & function testers
  • modular combination of more than 25 test methods possible
  • up to 250 test connections
  • large switch matrix modules for all kind test methods
  • PLe, SIL3, Kat4 Safety circuit (depending on device variant and degree of risk)
  • network
  • protocol & label printing
  • scanner …
  • Technology Package for even more ergonomics

read more

GLP3

Unlimited class leading test technology.

The TOP-Class of testing and measuring technology for safety and functional testing.

  • “All in one”
  • safety & function testers
  • for complex projects
  • for complex automation
  • for the highest demands
  • modular combination of more than 30 test methods
  • up to 350 test connections
  • large switch matrix modules for all kind test methods
  • PLe, SIL3, Kat4 safety circuit
  • Windows 10®
  • network
  • protocol & label printing
  • industry 4.0
  • interfaces to MES, ERP, SPS …

read more

TMUX4051: Graphs of leakage current vs. tempersature and ...

Hi Tyler,

as I understand it correctly, the worst case leakage currents published in the TMUX405x datasheet are similarily chosen to at least reach/best their classic counterparts (CD4051B or SN74HC4051 etc.) to be a drop in replacement (with a 1.8V logic advantage). Also the limits of these classic parts are/were dictated by measurement limits in production at the time of their introduction (decades ago), isn't it ?

So since the TMUX4051 is fabricated certainly in a much better process than those old parts (originally produced, when the datasheets were first written, 1970ies/80ies), I would expect that TYPICAL leakage perfromance is not worse than that of a modern high voltage precision analog switch like the MUX508, correct ?

I need leakage currents of less than 10nA at temperatures up to 60°C, or better than 1nA to be absolutely on the safe side, if some ageing/stress effects may come into play.

My investigations show, that even the old CD4051B, HC4051 and other more expensive contenders like the Vishay DG4051 etc. easily reach that performance, but some are unfortunately not specified/tested as such or much more expensive.

If  I were TI, I would specify/test the TMUX405x more aggressively in that regard to bring it close to the precision switch region, even if the yield goes down a little bit and (test) cost may go up a few cents. The market would certainly appreciate such a low budget precision switch product for cost sensitive applications (At least I do, I'm looking for a cost effective minaturized 8:1 MUX for quite a while).

Charge injection is not overly important for my application, but it would be nice to know, at which voltage the 0pC crossover point is, if it is a complementary switch.

Thank you,

Mirko

The company is the world’s best leakage current tester manufacturer supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.