TYPE S 12V 6.0L Jump Starter with Integrated JumpGuide

24 Jun.,2024

 

TYPE S 12V 6.0L Jump Starter with Integrated JumpGuide

If you have a TYPE S 12V 6.0L Jump Starter Power Bank With Jump Guide, a dead car is only a momentary inconvenience. This impressive device can easily jump start your battery and boasts several other features that make it indispensable for drivers of all types of vehicles.

Click here to get more.

Best Portable Car Battery Chargers & Jump Starters

A jump starter power bank provides enhanced convenience and safety. The best portable car battery chargers and jump starters should be small enough to fit in one of your vehicle's storage compartments. The TYPE S 12V 6.0L Jump Starter Power Bank measures 5.9 × 3.3 × 1.2 inches, meaning you can easily keep it in your glove box. A good power bank should also be able to charge other devices in addition to your car. The TYPE S 12V 6.0L Jump Starter has USB-A and USB-C charging ports to keep your devices charged while on the road.

What Is an LCD Jump Screen on a Jump Starter?

The TYPE S Power Bank includes an LCD screen that guides you, step by step, to ensure that you complete the jump-starting process correctly. If you still need a little more assistance to prevent any damage to your vehicle, the TYPE S Power Bank includes safeguards that prevent you from reversing the polarity.

Spark-Proof & Water-Resistant Jump Starter Power Bank

The TYPE S Power Bank is a spark-proof and water-resistant jump starter power bank, allowing you to safely start your vehicle in the pouring rain, driving snow, or any other extreme weather condition. Plus, the spark protections prevent you from damaging your battery or causing a fire.

If you have a TYPE S 12V 6.0L Jump Starter Power Bank With Jump Guide, a dead car is only a momentary inconvenience. This impressive device can easily jump start your battery and boasts several other features that make it indispensable for drivers of all types of vehicles.

Best Portable Car Battery Chargers & Jump Starters

A jump starter power bank provides enhanced convenience and safety. The best portable car battery chargers and jump starters should be small enough to fit in one of your vehicle's storage compartments. The TYPE S 12V 6.0L Jump Starter Power Bank measures 5.9 × 3.3 × 1.2 inches, meaning you can easily keep it in your glove box. A good power bank should also be able to charge other devices in addition to your car. The TYPE S 12V 6.0L Jump Starter has USB-A and USB-C charging ports to keep your devices charged while on the road.

What Is an LCD Jump Screen on a Jump Starter?

The TYPE S Power Bank includes an LCD screen that guides you, step by step, to ensure that you complete the jump-starting process correctly. If you still need a little more assistance to prevent any damage to your vehicle, the TYPE S Power Bank includes safeguards that prevent you from reversing the polarity.

Spark-Proof & Water-Resistant Jump Starter Power Bank

The TYPE S Power Bank is a spark-proof and water-resistant jump starter power bank, allowing you to safely start your vehicle in the pouring rain, driving snow, or any other extreme weather condition. Plus, the spark protections prevent you from damaging your battery or causing a fire.

Flexible Cords, Cables and Fixture Wire

While a strain-relief fitting is optional, other types of fittings may not be. You must use bushings or fittings to protect cords where they pass through holes in covers, outlet boxes, or similar enclosures [400.14].

While you normally can't install flexible cords in raceways, there is a provision in the Code that allows cords inside raceways for a specific type of installation. In industrial establishments where the conditions of maintenance and supervision ensure that only qualified persons will service the installation, you can install flexible cords or flexible cables in aboveground raceways &#; but only if the cords/cables aren&#;t more than 50 ft long [400.14].

Overcurrent protection

Flexible cords and cables must be protected against overcurrent in accordance with 240.5, which contains the following requirements:

  • Overcurrent devices must not be rated higher than the cord&#;s ampacity, as specified in Table 400.5(A) and Table 400.5(B) [240.5(A)].
  • Flexible cord for listed utilization equipment is considered protected when used per the equipment listing requirements [240.5(B)(1)].
  • Extension cord sets are considered protected when used per the extension cord listing requirements [240.5(B)(3)].
  • Flexible cord used in field-assembled extension cords, made with separately listed and installed components, can be supplied by a 20A branch circuit for 16 AWG and larger conductors [240.5(B)(4)].

Conductor identification

How do you know which conductor in a cord is the neutral? It must be identified using one of the following methods [400.22]:

  • White or gray colored braid.
  • Colored tracer in the braid.
  • White, gray, or light blue insulation.
  • Ridges, grooves or white stripes on the exterior of the cord.

The equipment grounding conductor must be identified with one of the following methods [400.23]:

You will get efficient and thoughtful service from Mingda.

  • Continuous green color.
  • Continuous identifying marker distinguishing it from the other conductors.

If a conductor in a cord or cable has insulation that's green or green with one or more yellow stripes, don't use it for an ungrounded or neutral conductor [250.119].

Fixture wires

Fixture wires are flexible conductors used for wiring fixtures and control circuits, but not branch circuits. There are some special uses and requirements for fixture wires, and NEC Art. 402 deals especially with fixture wires. Some key points:

  • No fixture wire can be smaller than 18 AWG [402.6].
  • Fixture wires must be of a type listed in Table 402.3. That table makes up the bulk of Art. 402.
  • The allowable ampacity of fixture wires is in Table 402.5.

Raceway size

Raceways must be large enough to permit the installation and removal of conductors without damaging conductor insulation [402.7]. The number of fixture wires permitted in a single raceway must not exceed the percentage fill specified in Table 1 of Chapter 9.

When all conductors in a raceway are the same size and insulation, you can use Annex C to determine the number of conductors permitted for the raceway type.

When all conductors are not of the same insulation type or the same size, then Chapter 9, Table 5 is used to find the area of all conductors, and Chapter 9, Table 4 is then used to size the raceway that can accommodate that conductor fill.

Neutral identification

The fixture wire used as a neutral conductor must have continuous white stripes or be identified by one of the means allowed for the neutral of flexible cords and cables as listed in 400.22(A) through (E) [402.8]. Always remember that in order to prevent electric shock, the screw shell of a luminaire or lampholder must be connected to the neutral conductor [200.10(C) and 410.50].

Permitted uses

You can use fixture wires:

  • For installation in luminaires (and similar equipment), where enclosed and protected and not subject to bending and twisting in use [402.10].
  • To connect luminaires to their branch circuit conductors [402.10].
  • For elevators and escalators [620.11(C)], Class 1 control and power-limited circuits [725.49(B)], and nonpower-limited fire alarm circuits [760.49(B)].

You can't use fixture wires, however, for branch-circuit wiring, except as permitted elsewhere in the Code [402.11].

Overcurrent protection

Fixture wires are allowed to be tapped off of a branch-circuit conductor following the requirements of [240.5(B)(2)]:

  • 20A circuits can supply: 18AWG, up to 50 ft of run length; 16AWG, up to 100 ft; 14AWG and larger for any length.
  • 30A circuits can supply: 14AWG and larger.
  • 40A and 50A circuits can supply: 12AWG and larger.

Fixture wires used for motor control circuit taps must have overcurrent protection per 430.72(A), and Class 1 remote-control circuits must have overcurrent protection per 725.43.

The requirements for flexible cords, cables, and fixture wires aren't hard to meet; however, violating them can cause serious problems. Always remember that the rules for flexible cords and cables are in Art. 400 and fixture wires are covered by Art. 402, then start by using the tables in these articles for application and ampacity details.

For more information on this topic, read "Flexible Cords and Flexible Cables."